Johnson-systems JS-ICON Series Dimmer/Relay Rack (2410,2413,1220,1 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Oświetlenie Johnson-systems JS-ICON Series Dimmer/Relay Rack (2410,2413,1220,1. Johnson Systems JS-ICON Series Dimmer/Relay Rack (2410,2413,1220,1210/620) User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
User Manual
JS-ICON
Series
Dimmer/Relay Rack
JS-ICON
2410
JS-ICON
2413
JS-ICON
1220
JS-ICON
1210/620
JOHNSON SYSTEMS INC.
www.johnsonsystems.com
2002161
Przeglądanie stron 0
1 2 3 4 5 6 ... 33 34

Podsumowanie treści

Strona 1 - User Manual

User ManualJS-ICON™ SeriesDimmer/Relay RackJS-ICON™ 2410JS-ICON™ 2413JS-ICON™ 1220JS-ICON™ 1210/620JOHNSON SYSTEMS INC.www.johnsonsystems.com2002161

Strona 2 - For Technical Assistance

www.johnsonsystems.com10J24J23J18J17J33J30J29J28J27J26J21J20J19J16J15PS1J1J3J2J6J4J8J7 J10J9J12J5J11J14J13J32INPUTVAC26485WATTS15DCVOLTS12SUPPLYPOWERT

Strona 3 - Introduction

www.johnsonsystems.com 11MAINTAINEDNORMALLY OPENSWITCH CONTACTO/TFIRESCTYAUXCOMEEPROM MEMORY MODULE EEPROM BACKUP & FIRMWARE UPDATE EDGE1 R1 R2 D

Strona 4 - Characteristics

www.johnsonsystems.com12LCD DisplayInfrared LEDProgrammingSwitchesSystemStatusLED IndicatorsAB AUser InterfaceThe user interface provides access to al

Strona 5 - Installation

www.johnsonsystems.com 13System Status - LED IndicatorsRUN (Green)Illuminates when the power is on, and the microcontroller status is in normal run mo

Strona 6 - (Example shown to the left)

www.johnsonsystems.com14INF HOLDDisplayed when DMX is disconnected, and the systems predetermined DMX status hold (SH) time is set for innite (INF) h

Strona 7

www.johnsonsystems.com 15Quick Programming Reference to System Configuration Menu Items1. SCENESET Enable and setup 24 different backup scenes.2. FADE

Strona 8 - Ground Connection Details

www.johnsonsystems.com16Detailed Programming of System Configuration Menu ItemsNOTE: The programming switches can be locked out to prevent inadvertent

Strona 9 - Dimmer Output

www.johnsonsystems.com 173. SNAPSHOT Record DMX levels into the backup scenes. Provides a quick and easy way to save control channel levels into e

Strona 10 - +12VDC Power Supply Output

www.johnsonsystems.com187. DMX MODE Congure the mode of the on-board DMX protocol manager. There are ve different mode settings for the DMX pro

Strona 11 - Memory Module

www.johnsonsystems.com 1910. DMXB TRM Enable or disable termination on the DMX B input. Activates and deactivates a 120Ω termination resistor. DM

Strona 12 - User Interface

www.johnsonsystems.com2WarrantyJS-ICON™ Series dimmer racks come with a standard 1 year limited warranty. Extended warranties of up to 10 years are av

Strona 13 - System Status - LCD Display

www.johnsonsystems.com20 If a dimmer is patched to both DMX A and DMX B input channels, the DMX levels are merged and highest-takes-precedence (HTP

Strona 14

www.johnsonsystems.com 2114. SH TIME Set the DMX status hold time from 0 to 99 minutes or innite. When DMX is disconnected the system will hold

Strona 15

www.johnsonsystems.com2217. VOUT LIM Set the maximum RMS output voltage for each dimmer. Limiting the maximum RMS voltage can greatly improve lam

Strona 16

www.johnsonsystems.com 2321. ANA TEST View the control level for each of the analog inputs. The analog voltage level for the 4 analog inputs can

Strona 17 - channels

www.johnsonsystems.com24 A+D< 001 Displays the active trigger mode as analog and DMX (A+D<) channel 001. A+D> 001 Press EXECUTE to toggle

Strona 18

www.johnsonsystems.com 2530. F-ALARM Select the level and control channels triggered by the re alarm input. When a contact is sensed on the re a

Strona 19

www.johnsonsystems.com2633. POLARITY Set the PWM output control polarity. Locked for factory use only! This menu is only used when swapping the MA

Strona 20

www.johnsonsystems.com 2739. HARD-KEY View the microcontroller’s unique six-character hard-key code. JS-ICON™ Series dimmer racks may be shipped w

Strona 21

www.johnsonsystems.com2843. FW-LOAD Load new rmware into the MADD-24 via the EEPROM memory module. If a rmware update is required, Johnson Syste

Strona 22

www.johnsonsystems.com 29 RESTART When parameter restore is complete, the system restarts. SERIAL # Displayed when the silicone serial number on

Strona 23

www.johnsonsystems.com 3IntroductionJS-ICON™ Series wall-mount dimmer racks represent the ultimate value in hi-performance dimming! Next generation “s

Strona 24

www.johnsonsystems.com30 SCENE>FL Press MENU ( ) to select the desired scene (01 to 24) or all scenes (FL). V-LIMIT? Prints the output vo

Strona 25

www.johnsonsystems.com 31JSI Serial Number: ___________________Silicone Serial Number: _______________Hard-Key Code: _____________________JSI Seria

Strona 26

www.johnsonsystems.com32Troubleshooting ReferenceThis manual is accurate at time of printing and subjectto revisions and technical updates as required

Strona 27

www.johnsonsystems.com 33Troubleshooting ReferenceThis manual is accurate at time of printing and subjectto revisions and technical updates as require

Strona 28

www.johnsonsystems.comJS-ICON™ 122012 x 20 Amp (2400 Watt) dimmersJS-ICON™ 241024 x 10 Amp (1200 Watt) dimmersJS-ICON™ 241324 x 13 Amp (1560 Watt) dim

Strona 29

www.johnsonsystems.com4Characteristics• Maximum Feeder Capacity: 100 Amp 120/208 VAC 3Ø 5 wire. Max. Rating 28.8kW. 100 Amp 120/240 VAC 1Ø 4 wire. Ma

Strona 30

www.johnsonsystems.com 512" Minimum Clearance for Hot Air Exhaust18" Minimum Clearance KEEP CLEAR12" Minimum Clearance for Cool Air Int

Strona 31

www.johnsonsystems.com6Power Supply Connection DetailsThe JS-ICON™ Series dimmer racks are capable of various 120V power supply congurations. The con

Strona 32 - Troubleshooting Reference

www.johnsonsystems.com 7Power Supply Connection DetailsPower Supply Configurations - Single Phase:120/240 VAC, 1Ø, 4-Wire up to 100 Amps per phase. Max

Strona 33

www.johnsonsystems.com8Load Circuit Neutral Output TerminalsLoad Circuit NeutralsGround InputLoad Circuit GroundsPower Supply Connection DetailsNeutra

Strona 34 - Series Dimmer/Relay Racks

www.johnsonsystems.com 912 345 6789101311 12 14 15 16 17 18 19 20 21 22 23 24Load OutputTerminal BlocksLine VoltageAC Wire / ConduitEntryLine VoltageA

Komentarze do niniejszej Instrukcji

Brak uwag